374
Query Command Library
observations has been set to be user defined (see
$PASHS,SOM).
Command Format Syntax
$PASHQ,SOM,NAV[*cc]
Parameters
None.
Response Format Syntax
$PASHR,SOM,NAV,s1,s2*cc
Parameters
Example
$PASHQ,SOM,NAV
$PASHR,SOM,NAV,ON,ON*50
Relevant Set
Command
$PASHS,SOM,NAV
See Also $PASHS,SOM
SOM,SNR: Signal-to-Noise Ratio Mask
Function This command is used to read the current setting of the
signal-to-noise ratio mask applied to signal observations. This
mask is active only when applying masks to signal
observations has been set to be user defined (see
$PASHS,SOM).
Command Format Syntax
$PASHQ,SOM,SNR[*cc]
Parameters
None.
Parameter Description Range Default
s1 Mask applied to differential data ON, OFF ON
s2 Mask applied to raw data ON, OFF OFF
*cc Checksum *00-*FF