349
Query Command Library
RDP,LVL: Reading the Radio Reception Level
Function This command is used to read the current level of signal at
the radio receiver input. Only U-Link Rx and license-free
radio receivers can return the current value of this parameter.
Command Format Syntax
$PASHQ,RDP,LVL,c[*cc]
Parameters
Response format Syntax
$PASHR,RDP,LVL,d1*cc
Parameters
Example
With U-Link Rx as the internal radio connected to port D:
$PASHQ,RDP,LVL,D*23
$PASHR,RDP,LVL,D,-100*10
See Also $PASHS,RDP,PAR
$PASHS,RDP,TYP
RDP,PAR: Radio Parameters
Function This command allows you to query the radio settings relevant
to the port used to communicate with the radio.
Command Format Syntax
$PASHQ,RDP,PAR,c1[*cc]
Parameter Description Range
c
Identification of the port to which the internal radio
receiver is connected.
A, D
*cc Optional checksum *00-*FF
Parameter Description Range
d1 Signal level, in dBm
*cc Optional checksum *00-*FF