User’s Manual – Conventional Mode
164
3. Define your horizontal curve by making the
appropriate selections from the first two
buttons and filling in the corresponding
values.
4. Enter the station to be assigned to the PC
in the PC Station field.
5. Check the Interval box if you want to
compute data for stations at fixed intervals
on the curve and enter the distance
between them in the same field.
6. Enter the station that you want to compute
in the Current Station field and tap Solve.
7. Tap the Results tab to view the numerical information for the
location of the current station. Tap the Map tab to view a graphic
of the current station on the curve.
8. Tap Sta + to advance the current station by the specified station
interval or tap Sta - to subtract the station interval from the
current station.