Survey Pro Reference Manual
R-38
Repetition Settings
The Repetition Settings card contains the settings that control how
repetition shots are performed and acceptable tolerances.
Horizontal Tolerance
: a warning message will be
displayed if a horizontal angle exceeds the tolerance
entered here during a repetition shot.
Zenith Tolerance
: a warning message will be displayed if
a vertical angle exceeds the tolerance entered here
during a repetition shot.
Distance Tolerance
: a warning message will be
displayed if a distance exceeds the tolerance entered
here during a repetition shot.
Shoot Distance To Backsight
: When checked, a
distance will be measured to each shot to the backsight.
When unchecked, only the angles are measured.
Do Not Shoot Reverse Distances
: When checked,
distances are not measured during reverse shots.
Enable Automatic Repetition
: When checked, all remaining shots
after the first shot to the backsight and foresight will occur
automatically when using a motorized instrument.
Shooting Sequence
: specifies the order that the shots are taken from
the following options:
BS > FS ^ FS > BS
: Backsight, Foresight, flop Foresight
Backsight
BS > FS ^> BS > FS
: Backsight, Foresight, flop Backsight,
Foresight
BS ^ BS > FS ^ FS
: Backsight, flop Backsight, Foresight, flop
Foresight
FS ^ FS > BS ^ BS
: Foresight, flop Foresight, Backsight, flop
Backsight
FS > BS ^ BS > FS
: Foresight, Backsight, flop Backsight,
Foresight
Przeglądanie stron 43