Stake Points
The Stake Points screen allows you to stake a single point or a series
of points.
: located at the top of the screen, accesses the
Stakeout Settings screen (Page R-35).
Design Point
: is the name of the first point that you
want to stake.
Increment
: when advancing to the next point, the point
number is incremented by the value entered here. (A
negative integer can be entered to have point numbers
advance in descending order.)
: advances the current
Design Point
by the
Increment
value. If that point does not exist and the
Increment
value =1, the
Design Point
is advanced to the
next existing point.
Height of Rod
: is the length of the rod.
: accesses the Backsight Setup
screen (Page R-78).
: takes you to the second Stake Points
screen where the
distance and direction to the design point is displayed, see below.