Users Manual
24
Repetition Settings
The Repetition Settings contains the settings that control how
repetition shots are performed and the acceptable tolerances.
Horizontal Tolerance
: a warning message will be
displayed if a horizontal angle exceeds the
tolerance entered here during a repetition shot.
Zenith Tolerance
: a warning message will be
displayed if a vertical angle exceeds the
tolerance entered here during a repetition shot.
Distance Tolerance
: a warning message will be
displayed if a distance exceeds the tolerance
entered here during a repetition shot.
Shoot Distance To Backsight
: when checked, a
distance will be measured to each shot to the
backsight. When unchecked, only the angles are measured.
Do Not Shoot Reverse Distances
: when checked, distances are not
measured during reverse shots.
Enable Automatic Repetition
: when checked, all remaining shots
after the first shot to the backsight and foresight will occur
automatically when using a motorized instrument.
Shooting Sequence
: specifies the order that the shots are taken from
the following options:
BS > FS ^ FS > BS
: Backsight, Foresight, flop, Foresight
Backsight
BS > FS ^ > BS > FS
: Backsight, Foresight, flop, Backsight,
Foresight
BS ^ BS > FS ^ FS
: Backsight, flop, Backsight, Foresight, flop,
Foresight
FS ^ FS > BS ^ BS
: Foresight, flop, Foresight, Backsight, flop,
Backsight
FS > BS ^ BS > FS
: Foresight, Backsight, flop, Backsight,
Foresight
Przeglądanie stron 29