Users Manual
144
Performing a Traverse Adjustment
1. Tap , from the Main Menu.
2. Use the or button
to select the polyline or points that define
your traverse, which should be in the same
order that the traverse points were collected.
3. Select the appropriate checkboxes to define
the type of adjustment(s) to perform and
what will be adjusted.
4. Tap to continue to the next screen.
The screen that opens will depend on the
selections made from the main screen.
5. If an angle adjustment is being performed,
the screen shown here will open. Enter the
closing angle for the traverse in the form of
an angle-right.
6. Tap to open the next screen of the
adjustment wizard.
7. If a Compass Rule adjustment is being
performed, the screen shown here will open.
Select
Closed Traverse
if you are adjusting a
closed traverse or select
Close to Known
Location
if you are adjusting an open traverse
and closing to a known point or location. A
closing location can be defined by an existing
point or known coordinates by toggling the
/ button accordingly.